Roof PINRoof PIN

Concrete

The Roof-PIN type S can be used on concrete ceilings and walls. The Roof-PIN type S is attached to the subsurface with 4 bolt anchors. The mounting plate is designed in such a way that there is always a complete support.
The height of the Roof-PIN is delivered pre-assembled to the required insulation thickness.

 

product types

Bitte wählen
  • elevation on concrete with roof membrane and ringnut
  • elevation on concrete with roof membrane and "cable guide"
  • elevation on concrete with bitumen sheeting and ringnut
  • elevation on concrete with bitumen sheeting and "cable guide"

The Roof-PIN type S is attached to the concrete with 4 bolt anchors. The seal is made with a roof membrane, which is clamped between the lower part with thermocouple fixed on the supporting shell and the upper part. For this purpose, the roof membrane is only punctured minimally and the puncture point is also slightly elevated, which guarantees long-term impermeability.
This is a single attachment point, where only the upper part has to be replaced when it is used. The roof skin does not have to be opened to replace the bent anchorage point.

Roof-PIN type S on concrete with roof membrane and ringnut

The Roof-PIN type S is attached to the concrete with 4 bolt anchors. The seal is made with a roof membrane, which is clamped between the lower part with thermocouple fixed on the supporting shell and the upper part. For this purpose, the roof membrane is only punctured minimally and the puncture point is also slightly elevated, which guarantees long-term impermeability.
This is an attachment point for "cable guides" where only the upper parts have to be replaced when used. The roof skin does not have to be opened to replace the bent attachment points.

Roof-PIN type S on concrete with roof membrane and "cable guide"

The Roof-PIN type S is attached to the concrete with 4 bolt anchors. The seal is made with a roof membrane, which is clamped between the lower part with thermocouple fixed on the supporting shell and the upper part. For this purpose, the roof membrane is only punctured minimally and the puncture point is also slightly elevated, which guarantees long-term impermeability.
This is a single attachment point, where only the upper part has to be replaced when it is used. The roof skin does not have to be opened to replace the bent anchorage point.

Roof-PIN type S on concrete with bitumen sheeting and ringnut

The Roof-PIN type S is attached to the concrete with 4 bolt anchors. The seal is made with a roof membrane, which is clamped between the lower part with thermocouple fixed on the supporting shell and the upper part. For this purpose, the roof membrane is only punctured minimally and the puncture point is also slightly elevated, which guarantees long-term impermeability.
This is an attachment point for "cable guides" where only the upper parts have to be replaced when used. The roof skin does not have to be opened to replace the bent attachment points.

Roof-PIN type S on concrete with bitumen sheeting and "cable guide"